{"id":3305,"date":"2021-01-31T10:32:35","date_gmt":"2021-01-31T15:32:35","guid":{"rendered":"http:\/\/rv10.mirimar.org\/?p=3305"},"modified":"2021-02-02T11:34:27","modified_gmt":"2021-02-02T16:34:27","slug":"instrument-panel-3","status":"publish","type":"post","link":"https:\/\/rv10.mirimar.org\/?p=3305","title":{"rendered":"Instrument Panel (3)"},"content":{"rendered":"<p>Progress was made over the holidays by taking advantage of the social distance rules enforced in our area to focus on individual work.<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9557.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3266 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9557-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9557-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9557-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9578.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3268 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9578-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9578-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9578-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The sub-panel was modified to accept the VPX-Pro electronic circuit breaker box.\u00a0 Here the raw opening was cut, followed by layout of the rivet and fastener holes for a backing plate.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9580.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3269 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9580-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9580-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9580-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9582.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3270 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9582-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9582-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9582-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The final holes for the VPX opening are drilled.\u00a0 The blue tape shows the future location of the primary and secondary voltage regulators (B&amp;C LR3C-14).\u00a0 The untreated backing plates on the right picture were clecoed for test fits.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9603.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3279 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9603-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9603-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9603-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9623.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3289 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9623-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9623-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9623-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The backing plates and mounting brackets were prepared for the standard alodine treatment, which consists of scuff, degrease, acid wash, rinse, alodine dip, rinse again and hang to dry.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9605.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3280 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9605-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9605-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9605-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9648.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3300 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9648-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9648-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9648-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The alodined ANL fuse\/shut brackets are on the left.\u00a0 At right are the completed brackets painted Boeing 707 Gray and bolted together.\u00a0 Notice the copper bridge used between the ANL fuse and shunt. The raw bus bar stock of 1\/8&#8243; x 1\/2&#8243; copper is rated for 250Amps, plenty for this location. The bracket will eventually be mounted on the engine side of the upper firewall.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9636.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3295 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9636-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9636-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9636-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9635.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3294 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9635-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9635-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9635-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The cockpit side of the firewall will mount the GAD29 ARINC Adapter (left) and the GEA24 Engine Monitor devices.\u00a0 The GEA24 bracket also serves as the mount point for the B&amp;C GB24\/48 ground blocks.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9632.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3293 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9632-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9632-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9632-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9631.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3292 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9631-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9631-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9631-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>Firewall penetrations for the terminal posts were supported by a backing plate. The nylon attachment point will secure the #2 wire from the GB24\/48 ground block to the batteries which are located in the rear behind the baggage bulkhead.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9626.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3290 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9626-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9626-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9626-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9627.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3291 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9627-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9627-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9627-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The finished VPX-Pro mounting bracket fits perfectly in the corresponding cutout in the sub-panel (shown above).<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9590.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3272 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9590-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9590-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9590-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-thumbnail wp-image-3271\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9588-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9588-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9588-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/>The alodined backing plates were clecoed to the sub-panel prior to riveting.\u00a0 The right photos shows #8 nutplates being riveted onto the inspection port backer.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9593.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3273 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9593-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9593-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9593-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9594.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3274 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9594-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9594-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9594-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The inspection port backer riveted in place as seen from in front and behind the sub-panel.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9597.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3276 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9597-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9597-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9597-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9607.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3281 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9607-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9607-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9607-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>A reinforcement plate was fabricated to strengthen the VPX-Pro cutout hole and provide a mounting point for Adel clamps to secure cabling.\u00a0 On the right the DRDT-2 was used to dimple the dashboard for the panel fan backers.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9610.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3282 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9610-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9610-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9610-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9611.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3283 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9611-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9611-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9611-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The panel fans will be 80mm brushless computer fans with a high cfm ratng.\u00a0 They are very loud at full power, but speeds will be adjustable for correct cooling by a rheostat on the panel.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9598.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3277 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9598-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9598-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9598-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9600.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3278 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9600-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9600-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9600-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The dashboard skin is very thin (.032&#8243;) near the handle grips.\u00a0 To help strengthen this area for routine operations, a fiberglass reinforcement piece will be added.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9615.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3285 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9615-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9615-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9615-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9621.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3288 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9621-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9621-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9621-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The primary and secondary circuits from the rear mounted batteries to the firewall terminals use #2 wire.\u00a0 The terminals are also attached to a cross-tie contactor &#8211; the single joint connection point between the two separate buses.\u00a0 A test fit of a tee-shaped boot shows how the terminal posts will be insulated.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9617.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3287 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9617-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9617-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9617-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9616.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3286 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9616-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9616-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9616-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>On the engine side of the firewall the terminal posts connect to the starter contactor with #2 wire, and to the shunts with #6 wire.\u00a0 The right photos shows the #2 ground wire on the cockpit side bolted to the GEA24 mounting bracket.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9640.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3297 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9640-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9640-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9640-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9642.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3298 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9642-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9642-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9642-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The large #2 battery wires were crimped with a YQK-300 16ton Hydraulic Crimper. At the recommendation of electrical experts in the community the terminal lugs were lightly soldered at the tips just to secure an electrical connection to the wire.\u00a0 The solder should not wick into the flexible wire area as the heavily crimped section should be cold fused together to prevent penetration. At least that is the theory&#8230;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9643.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3299 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9643-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9643-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9643-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>Completed terminal wires were heat shrink wrapped for insulation and protection.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9659.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3302 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9659-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9659-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9659-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9658.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3301 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9658-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9658-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9658-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>Because the default wire for GTP59 Outside Air Temperature probe arrived too short to reach an appropriate mounting location in the left wing, the default termination to the GSU25 ADAHRS unit needed to be replaced with a longer wire. Prior to the re-pinning effort, the DB15 configuration was photographed.\u00a0 The extracted J252 Pins 1,2,3 were then replaced with new wire.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9662.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3303 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9662-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9662-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9662-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>A common termination point for aircraft ground wires near the instrument panel provides a direct, high quality electrical pathway back to the batteries.\u00a0 In addition, the colocation of labelled wires will help future troubleshooting activities.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9637.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3296 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9637-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9637-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9637-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><a href=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9664.jpg\" data-rel=\"lightbox-gallery-rMeb6t4Y\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-3304 size-thumbnail\" src=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9664-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9664-150x150.jpg 150w, https:\/\/rv10.mirimar.org\/wp-content\/uploads\/2021\/01\/IMHF9664-200x200.jpg 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>The sub-panel inspection port serves a dual function as being the mounting location for the secondary bus fuse block (Bussman 17512-24). \u00a0 On the completed fuse block &#8216;dumb&#8217; devices (panel fans, floor lights, overhead lights, etc.) are bench tested with a 14.4V switching power supply. So far, so good.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Next steps are checking wire runs and functions on the main G3X devices and avionics.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Progress was made over the holidays by taking advantage of the social distance rules enforced in our area to focus on individual work. The sub-panel was modified to accept the VPX-Pro electronic circuit breaker box.\u00a0 Here the raw opening was cut, followed by layout of the rivet and fastener holes for a backing plate. &nbsp; <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/rv10.mirimar.org\/?p=3305\" class=\"more-link\"><span>Continue Reading &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39,73,10],"tags":[],"class_list":["post-3305","post","type-post","status-publish","format-standard","hentry","category-custom-elements","category-instrument-panel","category-rv-10-build-project"],"_links":{"self":[{"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/posts\/3305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3305"}],"version-history":[{"count":9,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/posts\/3305\/revisions"}],"predecessor-version":[{"id":3315,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=\/wp\/v2\/posts\/3305\/revisions\/3315"}],"wp:attachment":[{"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rv10.mirimar.org\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}